91欧美激情一区二区三区,aⅴ无码国产不卡免费播放,国产欧美久久久久,久久人妻制服乱码中文字幕

查看全部
當(dāng)前位置:首頁(yè)   >    產(chǎn)品中心   >    電壓擊穿試驗(yàn)儀   >    電壓擊穿強(qiáng)度試驗(yàn)儀   >   BDJC-50KV耐擊穿電壓強(qiáng)度測(cè)試儀 產(chǎn)品展示

耐擊穿電壓強(qiáng)度測(cè)試儀

型 號(hào)BDJC-50KV

更新時(shí)間2024-11-20

廠商性質(zhì)生產(chǎn)廠家

報(bào)價(jià)

產(chǎn)品描述:耐擊穿電壓強(qiáng)度測(cè)試儀主機(jī)體型:

主機(jī)尺寸:長(zhǎng)寬高-800*700*1600(MM)

操作臺(tái)尺寸:長(zhǎng)寬高-800*700*650(MM)

防護(hù)罩材質(zhì):白色透明有機(jī)玻璃

油槽尺寸:長(zhǎng)寬高-300*200*150

設(shè)備重量:約100KG

產(chǎn)品概述

耐擊穿電壓強(qiáng)度測(cè)試儀主機(jī)體型:

主機(jī)尺寸:長(zhǎng)寬高-800*700*1600(MM)

操作臺(tái)尺寸:長(zhǎng)寬高-800*700*650(MM)

防護(hù)罩材質(zhì):白色透明有機(jī)玻璃

油槽尺寸:長(zhǎng)寬高-300*200*150

設(shè)備重量:約100KG


耐擊穿電壓強(qiáng)度測(cè)試儀整機(jī)組成:

1、升壓部件:由調(diào)壓器和高壓變壓器組成0~50KV的升壓部分。

2、動(dòng)部件:由步進(jìn)電機(jī)均勻調(diào)節(jié)調(diào)壓器使加給高壓變壓器的電壓變化。

3、檢測(cè)部件:由集成電路組成的測(cè)量電路。通過(guò)信號(hào)線把檢測(cè)的模擬信號(hào)和開關(guān)信號(hào)傳給計(jì)算機(jī)。

4、計(jì)算機(jī)軟件:通過(guò)智能電路把由檢測(cè)設(shè)備采集的測(cè)控信號(hào)傳給計(jì)算機(jī)。計(jì)算機(jī)根據(jù)采集的信息控制設(shè)備運(yùn)行并處理試驗(yàn)結(jié)果。

5、試驗(yàn)電極:根據(jù)國(guó)家標(biāo)準(zhǔn)(1408.1-2006)隨設(shè)備提供三個(gè)電極,具體規(guī)格為:Ф25mm×25mm兩個(gè);Ф75mm×25mm一個(gè)。


軟件功能:

01、軟件平臺(tái):WINDOWS窗口操作平臺(tái),界面直觀,便于操作

02、曲線顯示:在實(shí)驗(yàn)過(guò)程中可以動(dòng)態(tài)顯示試驗(yàn)曲線

03、數(shù)據(jù)導(dǎo)出:可以對(duì)試驗(yàn)結(jié)果導(dǎo)入EXCEL表格

04、實(shí)驗(yàn)報(bào)告:可以人為設(shè)置報(bào)告名稱,并對(duì)實(shí)驗(yàn)報(bào)告進(jìn)行打印

05、試驗(yàn)方式:可以根據(jù)需求對(duì)直流試驗(yàn)和交流試驗(yàn)進(jìn)行靈活選擇

06、試驗(yàn)方法:可以根據(jù)需求自行選擇擊穿電壓、耐壓試驗(yàn)、梯度試驗(yàn)

07、參數(shù)設(shè)置:可以根據(jù)不同的試驗(yàn)方式及試驗(yàn)方法靈活設(shè)置所需的不同參數(shù)值

08、試樣設(shè)置:可對(duì)不同標(biāo)準(zhǔn)的試樣參數(shù)靈活設(shè)置

09、人員管理:設(shè)置用戶名及密碼,不同的操作員登入進(jìn)行不同的試驗(yàn),互不影響

10、標(biāo)準(zhǔn)選擇:含有不同標(biāo)準(zhǔn),可根據(jù)需求自行選擇

11、連續(xù)操作:連續(xù)操作試驗(yàn)時(shí),可直接在軟件里選擇電機(jī)復(fù)位,進(jìn)行二次試驗(yàn)



技術(shù)指標(biāo):

01、輸入電壓: 交流 220 V

02、輸出電壓: 交流 0--100 KV ;

               直流 0—100 KV

03、電器容量: 10KVA

04、高壓分級(jí): 0-100KV

05、升壓速率:0.01-5.0kv

              (備注:滿足標(biāo)準(zhǔn)要求并可以根據(jù)用戶需求設(shè)定不同的升壓速率)

06、試驗(yàn)方式:

           直流試驗(yàn):1、勻速升壓  2、梯度升壓 3、耐壓試驗(yàn)

           交流試驗(yàn):1、勻速升壓 2、梯度升壓 3、耐壓試驗(yàn)

07、試驗(yàn)介質(zhì):空氣,試驗(yàn)油

08、安裝靈敏度較高的過(guò)電流保護(hù)裝置保證試樣擊穿時(shí)在0.05S內(nèi)切斷電源。

09、儀器配備先進(jìn)的故障報(bào)警系統(tǒng) 避免用戶操作故障儀器發(fā)生危險(xiǎn)。(上位機(jī)報(bào)警和下位機(jī)報(bào)警)


配置
01                   試驗(yàn)主機(jī)               一臺(tái)
02                   高壓發(fā)生器             一套

 03                   試驗(yàn)電極               二套 (國(guó)標(biāo)1408.1)
 04                   試驗(yàn)油箱               一只
05                   放電系統(tǒng)               一套
06                   控制系統(tǒng)               一套
07                   數(shù)據(jù)采集系統(tǒng)            一套
08                   試驗(yàn)軟件                一套 光盤
09                   計(jì)算機(jī)                  一套 品牌 可選 PC/EPC
10                   噴墨打印機(jī)              一臺(tái) 品牌
11                   產(chǎn)品使用說(shuō)明書           一份
12                   計(jì)量證書                 一份
13                   產(chǎn)品合格證               一份
14                   電子穩(wěn)壓器               一臺(tái)
15                   藍(lán)牙發(fā)射器               一支
16                   藍(lán)牙接收器               一支



安全保護(hù)功能:

◆ 試驗(yàn)在試驗(yàn)箱中進(jìn)行,試驗(yàn)箱門打開時(shí)電源加不到高壓變壓器輸入端,即高壓側(cè)無(wú)電壓。100KV測(cè)試設(shè)備高壓電極距離試驗(yàn)箱壁的zui近距離大于370mm,50KV測(cè)試設(shè)備高壓電極距離試驗(yàn)箱壁的zui近距離大于250mm,試驗(yàn)時(shí)即使人接觸箱壁也不會(huì)有危險(xiǎn)。

◆ 設(shè)備要安裝單獨(dú)的保護(hù)地線。接保護(hù)地線,主要是減少試樣擊穿時(shí)對(duì)周圍產(chǎn)生的較強(qiáng)的電磁干擾。也可避免控制計(jì)算機(jī)失控。

◆ 該試驗(yàn)設(shè)備的電路設(shè)有多項(xiàng)保護(hù)措施,主要有:過(guò)流保護(hù)、失壓保護(hù)、漏電保護(hù)、短路保護(hù)、直流試驗(yàn)放電報(bào)警等。

◆直流試驗(yàn)放電報(bào)警功能:在設(shè)備做完直流試驗(yàn)時(shí),當(dāng)開啟試驗(yàn)門時(shí)設(shè)備會(huì)自動(dòng)報(bào)警,直至使用設(shè)備上的放電裝置放電后報(bào)警會(huì)自動(dòng)取消.(注:因?yàn)橹绷髟囼?yàn)后不放電會(huì)危險(xiǎn)到人身安全,不能直接拿取電極,起到提醒使用人員放電以免造成人身傷害)。

◆ 試驗(yàn)放電裝置,隨主機(jī)為一體化,改進(jìn)了以往單獨(dú)配備一根放電桿的功能。


注意事項(xiàng):
1、介電擊穿強(qiáng)度試驗(yàn)儀安裝時(shí)應(yīng)具有獨(dú)立的接地線。
2、在開機(jī)前,操作者要首先熟悉操作方法。
3、儀器不能在有強(qiáng)烈腐蝕性氣體及有顆粒雜質(zhì)的氣體環(huán)境中使用。
4、試驗(yàn)環(huán)境溫度15度到25度之間,相對(duì)濕度60%到70%之間
5、試樣擊穿瞬間有火花產(chǎn)生并伴有聲響,屬正常現(xiàn)象。
6、每次更換試樣或接觸高壓電極時(shí)必須用高壓放電棒對(duì)高壓電極進(jìn)行放電,放電時(shí)間5秒以上。

7、每次進(jìn)行試驗(yàn)前,必須檢查儀器接地。


注:   其它未盡事宜請(qǐng),我們將竭誠(chéng)為您服務(wù)。


標(biāo)簽:

電壓擊穿試驗(yàn)儀,

介電擊穿強(qiáng)度試驗(yàn)儀,

耐電壓擊穿測(cè)試儀,

工頻電壓擊穿測(cè)試儀,

電壓擊穿儀,

工頻介電擊穿強(qiáng)度測(cè)定儀,

工頻耐電壓擊穿試驗(yàn)機(jī),

電壓擊穿試驗(yàn)機(jī),

絕緣材料電氣強(qiáng)度測(cè)試儀,

擊穿強(qiáng)度試驗(yàn)儀,

電氣強(qiáng)度測(cè)試儀,

介電強(qiáng)度試驗(yàn)機(jī),

擊穿電壓試驗(yàn)機(jī),

電氣介電強(qiáng)度試驗(yàn)儀,

固體絕緣材料電氣強(qiáng)度試驗(yàn)儀,

硫化橡膠工頻擊穿電壓強(qiáng)度耐電壓擊穿測(cè)定儀,

耐電壓擊穿強(qiáng)度試驗(yàn)儀,

工頻耐擊穿電壓試驗(yàn)儀,

固體電絕緣材料工業(yè)電源頻率下的介電擊穿電壓和介電強(qiáng)度的試驗(yàn)儀,

橡膠塑料薄膜工頻電壓或直流電壓下?lián)舸?qiáng)度和耐電壓的測(cè)試儀器。



當(dāng)前電壓  —顯示試驗(yàn)過(guò)程中實(shí)際電壓值,單位為KV;

當(dāng)前漏電流—顯示試驗(yàn)過(guò)程中實(shí)際漏電流值,單位為mA;

試驗(yàn)電壓  —試驗(yàn)過(guò)程中zui高電壓止,即擊穿電壓,單位為KV;

試驗(yàn)漏電流—試驗(yàn)中zui大漏電流值,單位為mA;

計(jì)    時(shí)—顯示高壓保持時(shí)間,當(dāng)電壓達(dá)到設(shè)定值時(shí),從耐壓時(shí)間設(shè)定值開始減計(jì)時(shí),直到零;

計(jì)    數(shù)—記錄試驗(yàn)次數(shù),zui大顯示5次,按:“清除"按鍵可以將數(shù)值清零;

啟    動(dòng)—此按鍵按下系統(tǒng)啟動(dòng),按照設(shè)置好的升壓速率升壓,計(jì)數(shù)器加1;

復(fù)    位—在任何時(shí)間,按下此鍵,系統(tǒng)將強(qiáng)制停止所有動(dòng)作:試驗(yàn)結(jié)束、高壓停止輸出、調(diào)壓器回到零位、報(bào)警復(fù)位;

清    除—按一下,計(jì)數(shù)器顯示值清零;

報(bào)    告—按下此鍵,系統(tǒng)切換到如圖(9)試驗(yàn)報(bào)告畫面;

設(shè)    置—按下此鍵,系統(tǒng)切換到如圖(8)設(shè)置畫面;

零位指示—當(dāng)調(diào)壓器歸零時(shí),次指示燈亮,如果在啟動(dòng)前看不到零位指示,則按一下“復(fù)位"鍵,等調(diào)壓器歸位后再啟動(dòng)設(shè)備;

上    頁(yè)—點(diǎn)擊此處頁(yè)面將切換到歡迎畫面。



Resistance breakdown voltage strength tester host body:
Host size: length width height -800*700*1600 (MM)
Operating table size: long width high -800*700*650 (MM)
Shield material: white transparent organic glass
Oil groove size: length width height -300*200*150
Equipment weight: about 100KG
The composition of the whole machine for resistance to breakdown voltage strength tester:
1, boost parts: by the regulator and the high-voltage transformer to form 0 ~ 50KV boost part.
2. Moving parts: the voltage change of the high voltage transformer is adjusted by the uniform adjustment of the stepping motor..
3, detection components: measurement circuit composed of integrated circuit. The analog signal and the switch signal are transmitted to the computer by the signal line..
4, computer software: through the inligent circuit to the detection equipment collected by the measurement and control signal to the computer. The computer controls the equipment according to the information and runs the test results..
5, the test electrode: according to the national standard (1408.1-2006) with the equipment provides three electrodes, specifications: diameter of 25mm * two; a diameter of 75mm x 25mm a.
The software function of resistance breakdown voltage strength tester:
01, the software platform: WINDOWS window operation platform, the interface is intuitive, easy to operate
02, curves show: in the experimental process can be dynamic display test curve
03. Data export: EXCEL can import the test results
04, the experiment report: can set the report name artificially, and print the experiment report
05. Test method: can choose the DC test and AC test according to the requirement.
06. Test methods: according to the demand of the choice of breakdown voltage, pressure test, gradient test
07, parameter setting: according to different test methods and test methods to set the different parameters flexibly
08. Sample setting: flexible setting for different standard sample parameters
09, personnel management: set the user name and password, different operators to log in for different tests, not affect each other
10, the standard choice: containing different standards, according to the demand to choose their own
11, continuous operation: continuous operation test can be directly in the software to select the motor reset, two trials
Resistance breakdown voltage strength tester technical index:
01. Input voltage: AC 220 V
02, output voltage: AC KV 0--100;
DC 0 - 100 KV
03, electrical capacity: 10KVA
04, high pressure classification: 0-100KV
05, boost rate: 0.01-5.0kv
(Note: meet the standard requirements and can set the different boost rate according to the user's needs)
06. Test methods:
DC test: 1, uniform step 2, gradient boost 3, pressure test
AC test: 1, uniform step 2, gradient boost 3, pressure test
07, test medium: air, test oil
08, the installation of the high sensitivity of the overcurrent protection device to ensure that the sample breakdown in the 0.05S within the power.
09, the instrument equipped with advanced fault alarm system to avoid the operation of the user is dangerous. (upper computer alarm and lower computer alarm)
Resistance breakdown voltage strength tester configuration
01 test host a
02 high voltage generator set
03 test electrode two (GB 1408.1)
04 test tank one
05 discharge system
06 control system
07 data acquisition system a set of
08 test software a disc
09 computer a brand optional PC/EPC
10 inkjet printer a brand
11 a copy of the product manual
12 measurement certificate 1
13 product certificate a copy
14 electronic regulator
15 Bluetooth transmitter
16 Bluetooth receiver
The safety protection function of the test instrument for resistance to breakdown voltage:
] test were carried out in a test case, test box door open power does not come to input end of the high voltage transformer, high voltage side voltage free. 100kV test equipment for high voltage electrode distance test chamber wall of the recent distance is more than 370 mm, high-voltage test equipment of high voltage electrode distance test chamber wall of the recent distance greater than 250mm, test even people who come in contact with the wall of the box will not be in danger.
The equipment to install a separate protective ground. Earth wire, the main is to reduce the sample breakdown of the strong electromagnetic interference generated around the. Can also avoid control computer control.
] the test equipment of circuit with several kinds of protective measures, mainly has: over-current protection, loss of voltage protection, leakage protection, short-circuit protection, DC discharge test alarm.
] DC discharge test alarm function: when we finish DC test equipment. When opening the door test equipment will automatically alarm until after using the device discharge discharge device alarm will automatically be cancelled. (Note: because the DC test on it would be dangerous to personal safety, can not be directly fetching electrode to caution the use of personnel discharge so as not to cause physical damage).
The test discharge device, with the host for the integration, improved in the past with separate a discharge pole function.
Attention to the test of resistance to breakdown voltage:
1, the dielectric breakdown strength tester should have independent grounding wire.
2, before the boot, the operator to first

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細(xì)地址:

  • 補(bǔ)充說(shuō)明:

  • 驗(yàn)證碼:

    請(qǐng)輸入計(jì)算結(jié)果(填寫阿拉伯?dāng)?shù)字),如:三加四=7
聯(lián)系人:陳丹
手機(jī):
18911395947
點(diǎn)擊這里給我發(fā)消息